Post-Incident Inspection: Steps Before You Restart Equipment Safely

When an incident occurs — a collision, an overload, an unexpected failure, a near-miss — equipment cannot simply be checked over and put back into use. UK regulation imposes specific duties on duty-holders before restart, and getting them wrong creates regulatory and operational risk. This article sets out a structured post-incident inspection process.

What counts as an incident

For inspection purposes, an “incident” includes:

  • Equipment failure during operation
  • Collisions, overloads or shock-loading
  • Unexplained operational behaviour — drift, vibration, noise
  • Near-misses involving the equipment
  • Significant environmental events — fire, flood, structural damage to surroundings
  • Prolonged out-of-service periods

Each of these can trigger duties under LOLER 9(3), PUWER, PSSR or the Health and Safety at Work Act.

Step 1 — Make safe and isolate

Immediately:

  • Take the equipment out of service
  • Isolate it electrically, mechanically and pneumatically as appropriate
  • Tag and lock-off
  • Restrict physical access if there is any risk of inadvertent use

Step 2 — Preserve the scene

For anything beyond a minor event:

  • Take photographs before anything is moved
  • Note witnesses and gather first-hand accounts
  • Preserve any failed components
  • Do not attempt cleanup or repair before investigation

If the incident is RIDDOR-reportable, preservation matters even more — the HSE may visit.

Step 3 — Notify the right people

Internally: the responsible engineer, safety lead and site manager. Externally, any of:

  • The HSE — if RIDDOR criteria are met
  • The insurer
  • Manufacturers — for equipment-related failures
  • The competent person who issued the last examination report

Do not skip the competent person — they need to know, and their input matters.

Step 4 — Investigation

A proper investigation answers:

  • What happened — sequence of events
  • Why it happened — immediate and root causes
  • What conditions made it possible
  • What controls failed
  • What needs to change to prevent recurrence

Investigation should be documented, not just discussed.

Step 5 — Engineering assessment

A competent person inspects the equipment with the incident context in front of them. The examination is not a routine LOLER check — it is a focused assessment of whether the equipment can return to safe use. Common assessments:

  • Structural integrity after impact or overload
  • Wire rope condition after shock-loading
  • Pressure vessel condition after thermal or pressure excursion
  • Control system behaviour after unexplained operation

Step 6 — Repair, modification or retirement

Three outcomes are possible: repair to original specification, modification to address the underlying issue, or retirement and replacement. Whichever route, document the decision and the rationale.

Step 7 — Verification before restart

After repair, the equipment is examined again to verify it is fit for use. For some incidents, this counts as a fresh thorough examination — confirm with your competent person. The examination report should reference the incident, the action taken and the basis for return-to-service approval.

Step 8 — Update records and feed forward

The asset register, maintenance schedule and inspection plan should all be updated. Operators should be briefed on what happened and what has changed. The investigation findings should feed your wider safety system.

Common mistakes

  • Restarting equipment based on a visual check alone
  • Skipping the competent person because the incident “looks minor”
  • Repairing without investigation, so the root cause stays in place
  • Failing to update records, leaving the next examination engineer blind to history

How ESiNet supports post-incident work

Network engineers carry out post-incident examinations across LOLER, PUWER and PSSR equipment to a consistent standard, with reports that document incident context, assessment findings and basis for restart.

Get in touch for a post-incident inspection.

Frequently asked questions

Is a post-incident examination always required?

Where the incident may have affected equipment safety, yes — under LOLER 9(3) and equivalent provisions in PSSR. For minor events, your competent person will advise.

Who pays for a post-incident inspection?

The duty-holder, in most cases. Insurance may cover it depending on the policy.

Can the same engineer who issued the last routine report carry out the post-incident examination?

Yes, and there is often value in continuity.

How quickly does a post-incident examination need to happen?

As quickly as the equipment is needed back in service. Many sites secure same-week visits for urgent cases.

Disclaimer: Inspection delivery follows standardised procedures, with outcomes dependent on equipment condition and statutory requirements.