Construction Site LOLER Compliance: A Site Manager’s Practical Guide

Construction sites concentrate more lifting equipment, in more configurations, used by more contractors, than almost any other UK environment. LOLER applies to every piece of it — from tower cranes to teleporters, slings to safety harnesses. For site managers, that breadth is exactly the challenge. This guide sets out a practical approach to LOLER compliance on a live construction site.

The principal contractor’s role

Under CDM 2015 and the wider HSWA framework, the principal contractor is responsible for ensuring statutory inspection of all lifting equipment used on site, regardless of which subcontractor owns it. That responsibility cannot be subcontracted away by relying on someone else’s paperwork — but it can be discharged by a clear system.

Pre-mobilisation: equipment register

Before any contractor brings lifting equipment on site, they should provide:

  • Equipment specification and serial number
  • Current Report of Thorough Examination
  • Operator competence records — CPCS, NPORS, equivalent
  • Maintenance schedule and recent records
  • Manufacturer manual or relevant data plate

Site induction should not complete without these records on file.

On-site: continuous checks

Construction sites change daily. Equipment is moved, configured, attached to different loads. A LOLER report issued a month ago covers the equipment, but not the daily reality. Build in:

  • Daily pre-use inspections by operators — signed off and filed
  • Weekly walk-rounds by the lifting supervisor
  • Toolbox talks covering recent defects, new equipment and near-misses
  • Clear escalation when defects are spotted

Lifting plans and risk-managed operations

Every non-routine lift needs a lifting plan signed off by the Appointed Person. The plan references the equipment, its rated capacity, the load, the environment and the LOLER status of every piece involved. This is where statutory inspection and operational safety intersect.

Tower cranes — the high-stakes case

Tower cranes have the most prescriptive regime: 12-month thorough examination, supplemented by ongoing inspection by competent operators and erection or dismantling oversight by a competent person. Wire ropes, slewing rings, structural connections and electrical systems all warrant specific attention. Many sites use a dedicated crane safety coordinator.

Hired equipment

Most construction lifting equipment is hired. The hire company is responsible for examination before delivery and for supplying the report — but the duty to operate compliantly transfers to the site once delivered. Check the report on receipt; do not assume it.

Accessories — the easy miss

Slings, shackles, eyebolts, chains and other lifting accessories all need 6-monthly thorough examination. They are the most easily missed equipment on site because they move between teams and storage points. A tagged identification system and central storage drives discipline here.

Defect reporting and response

Every site should have a single, well-known defect reporting route. When an operator stops work on a piece of lifting equipment, the equipment goes out of service, a tag goes on, and an engineer attends. Operators who report defects should be visibly supported, not penalised.

Project handover

At project end, the LOLER paperwork for site-owned equipment transfers with the asset. For hired equipment, records remain with the hire company. Either way, the principal contractor should leave the site with a clean record of every lifting examination during the project.

ESiNet on construction

We support construction sites with thorough examinations across the full lifting inventory — tower cranes, MEWPs, teleporters, hoists, accessories — to a consistent standard.

Request an inspection or get in touch for site-wide LOLER support.

Frequently asked questions

Does CDM 2015 change LOLER duties?

No. CDM sits alongside LOLER and clarifies coordination duties. LOLER duties are separate and remain with the duty-holder.

Who is the competent person for tower crane examination?

A specialist crane inspection engineer with documented experience on the specific crane type, typically holding LEEA or sector-equivalent accreditation.

Are MEWPs covered by 6-monthly or 12-monthly examination?

MEWPs that lift people fall in the 6-month bracket. The same applies to mast climbers and personnel hoists.

What if a subcontractor refuses to share their LOLER reports?

Their equipment should not be permitted on site. The principal contractor has the right and the duty to verify compliance before equipment is used.

Disclaimer: Inspection delivery follows standardised procedures, with outcomes dependent on equipment condition and statutory requirements.